Ducted Systems - FDUA Ducted Series (High Static Pressure)
FDUA100VNP1VF2
Cooling Capacity
Heating Capacity
Dimensions
10.0kW
11.2kW
Indoor 398x1150x650mm, Outdoor 845x970x370mm
| Set | FDUA100VNP1VF2 | ||
| Indoor | FDUA100VF2 | ||
| Outdoor | FDC100VNP | ||
| Power supply | Outdoor Unit | 1 Phase 230V 50Hz | |
| CapacityØ | Cooling T1 | kW | 10.0 (2.8-11.2) |
| Heating H1 | 11.2 (2.5-12.5) | ||
| InputØ | Cooling T1 | kW | 2.99 |
| Heating H1 | 2.88 | ||
| EER | Cooling T1 | 3.34 | |
| COP | Heating H1 | 3.89 | |
| Sound pressure level (JIS C9612)Ø | Indoor | dB (A) | P-Hi:43 Hi:42 Me:40 Lo:37 |
| Outdoor | 57 | ||
| Sound power level (JIS C9612) | Outdoor | dB(A) | 70 |
| Airflow | Indoor | l/s | P-Hi:650 Hi:600 Me:550 Lo:483 |
| External static pressure | Pa | 200 | |
| External dimensions (HXWXD) | Indoor | mm | 398x1150x650 |
| Outdoor | 845x970x370 | ||
| Net weight | Indoor | kg | 52 |
| Outdoor | 70 | ||
| Refrigerant piping | Liquid line | mm | Ø9.52 |
| Gas line | Ø15.88 | ||
| Connection method | Flare Connection | ||
| Refrigerant R410A | Quantity | kg | 2.55 |
| Pre charged to pipe length | m | 15 | |
| Maximum pipe length | m | 30 | |
| Supply air connection | mm | 348x898 | |
| Return air connection | mm | 348x898 | |
| Controller | RC-E5, RC-EX3 or RCN-KIT4-E2 | ||
| Safety pan | UA-SP2-EØ (Optional) | ||